ApplicationMonitorProps
Properties for defining a ApplicationMonitor
.
See https://www.alibabacloud.com/help/ros/developer-reference/aliyun-ga-applicationmonitor
Initializer
import ros_cdk_ga
ros_cdk_ga.ApplicationMonitorProps(
accelerator_id: typing.Union[str, IResolvable],
address: typing.Union[str, IResolvable],
listener_id: typing.Union[str, IResolvable],
task_name: typing.Union[str, IResolvable],
detect_enable: typing.Union[bool, IResolvable] = None,
detect_threshold: typing.Union[typing.Union[int, float], IResolvable] = None,
detect_times: typing.Union[typing.Union[int, float], IResolvable] = None,
options_json: typing.Union[IResolvable, typing.Mapping[typing.Any]] = None,
silence_time: typing.Union[typing.Union[int, float], IResolvable] = None
)
Properties
Name | Type | Description |
---|---|---|
accelerator_id |
typing.Union[str, ros_cdk_core.IResolvable] |
Property acceleratorId: The ID of the GA instance on which you want to perform the origin probing task. |
address |
typing.Union[str, ros_cdk_core.IResolvable] |
Property address: The URL or IP address that you want to probe. |
listener_id |
typing.Union[str, ros_cdk_core.IResolvable] |
Property listenerId: The ID of the listener on which you want to perform the origin probing task. |
task_name |
typing.Union[str, ros_cdk_core.IResolvable] |
Property taskName: The name of the origin probing task. |
detect_enable |
typing.Union[bool, ros_cdk_core.IResolvable] |
Property detectEnable: Specifies whether to enable the automatic diagnostics feature. |
detect_threshold |
typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable] |
Property detectThreshold: The threshold that is used to trigger the automatic diagnostics feature. |
detect_times |
typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable] |
Property detectTimes: The number of times that the threshold must be reached before the automatic diagnostics feature is triggered. |
options_json |
typing.Union[ros_cdk_core.IResolvable, typing.Mapping[typing.Any]] |
Property optionsJson: The extended options of the listener protocol that is used by the origin probing task. |
silence_time |
typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable] |
Property silenceTime: The silence period of the automatic diagnostics feature. |
accelerator_id
Required
accelerator_id: typing.Union[str, IResolvable]
- Type: typing.Union[str, ros_cdk_core.IResolvable]
Property acceleratorId: The ID of the GA instance on which you want to perform the origin probing task.
address
Required
address: typing.Union[str, IResolvable]
- Type: typing.Union[str, ros_cdk_core.IResolvable]
Property address: The URL or IP address that you want to probe.
listener_id
Required
listener_id: typing.Union[str, IResolvable]
- Type: typing.Union[str, ros_cdk_core.IResolvable]
Property listenerId: The ID of the listener on which you want to perform the origin probing task.
task_name
Required
task_name: typing.Union[str, IResolvable]
- Type: typing.Union[str, ros_cdk_core.IResolvable]
Property taskName: The name of the origin probing task.
The name must be 1 to 128 characters in length and can contain letters, digits, periods (.), underscores (_), and hyphens (-). The name must start with a letter.
detect_enable
Optional
detect_enable: typing.Union[bool, IResolvable]
- Type: typing.Union[bool, ros_cdk_core.IResolvable]
Property detectEnable: Specifies whether to enable the automatic diagnostics feature.
detect_threshold
Optional
detect_threshold: typing.Union[typing.Union[int, float], IResolvable]
- Type: typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable]
Property detectThreshold: The threshold that is used to trigger the automatic diagnostics feature.
Unit: percentage.Valid values: 0 to 100.The default value is 0, which indicates that the automatic diagnostics feature is not triggered.
detect_times
Optional
detect_times: typing.Union[typing.Union[int, float], IResolvable]
- Type: typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable]
Property detectTimes: The number of times that the threshold must be reached before the automatic diagnostics feature is triggered.
Valid values: 1 to 20. Default value: 1.
options_json
Optional
options_json: typing.Union[IResolvable, typing.Mapping[typing.Any]]
- Type: typing.Union[ros_cdk_core.IResolvable, typing.Mapping[typing.Any]]
Property optionsJson: The extended options of the listener protocol that is used by the origin probing task.
The options vary based on the listener protocol.
silence_time
Optional
silence_time: typing.Union[typing.Union[int, float], IResolvable]
- Type: typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable]
Property silenceTime: The silence period of the automatic diagnostics feature.
This parameter specifies the interval at which the automatic diagnostics feature is triggered. If the availability rate does not return to normal after GA triggers an automatic diagnostic task, GA must wait until the silence period ends before GA can trigger another automatic diagnostic task.If the number of consecutive times that the availability rate drops below the threshold of automatic diagnostics reaches the value of DetectTimes, the automatic diagnostics feature is triggered. The automatic diagnostics feature is not triggered again within the silence period even if the availability rate remains below the threshold. If the availability rate does not return to normal after the silence period ends, the automatic diagnostics feature is triggered again.Unit: seconds. Valid values: 300 to 86400. Default value: 300.