Skip to content

MetricRuleTemplateDeploymentProps

Properties for defining a MetricRuleTemplateDeployment.

See https://www.alibabacloud.com/help/ros/developer-reference/aliyun-cms-metricruletemplatedeployment

Initializer

import ros_cdk_cms
ros_cdk_cms.MetricRuleTemplateDeploymentProps(
  group_id: typing.Union[typing.Union[int, float], IResolvable],
  template_ids: typing.Union[IResolvable, typing.List[typing.Union[str, IResolvable]]],
  append_mode: typing.Union[str, IResolvable] = None,
  apply_mode: typing.Union[str, IResolvable] = None,
  enable_end_time: typing.Union[typing.Union[int, float], IResolvable] = None,
  enable_start_time: typing.Union[typing.Union[int, float], IResolvable] = None,
  notify_level: typing.Union[typing.Union[int, float], IResolvable] = None,
  silence_time: typing.Union[typing.Union[int, float], IResolvable] = None,
  webhook: typing.Union[str, IResolvable] = None
)

Properties

Name Type Description
group_id typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable] Property groupId: Apply group ID.
template_ids typing.Union[ros_cdk_core.IResolvable, typing.List[typing.Union[str, ros_cdk_core.IResolvable]]] Property templateIds: The ID list of the Alarm Template to be applied.
append_mode typing.Union[str, ros_cdk_core.IResolvable] Property appendMode: Template application policy.Value: all: Delete all rules created by the alarm template on the selected group, and then create a new alarm rule by the template (default). append: Delete the rules created by the alarm template on the selected group, and then create a new alarm rule based on the current template.
apply_mode typing.Union[str, ros_cdk_core.IResolvable] Property applyMode: How to apply templates.Value: GROUP_INSTANCE_FIRST: Application grouping instances are preferred.When applying an alarm template, the application grouping instance is preferred. If the instance does not exist in the application grouping, the rules in the template are ignored. ALARM_TEMPLATE_FIRST: Alarm template instances are preferred.When an alarm template is applied, an alarm rule is created regardless of whether the instance exists in the application group.
enable_end_time typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable] Property enableEndTime: The end time when the alarm takes effect.Value range: 0~23, indicating 00:59 to 23:59.
enable_start_time typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable] Property enableStartTime: The start time when the alarm takes effect.Value range: 0~23, indicating 00:00 to 23:00.
notify_level typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable] Property notifyLevel: The alert notification method.
silence_time typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable] Property silenceTime: Channel silence period.Unit: seconds.Default value: 86400. Note When the monitoring data continues to exceed the alarm rule threshold, only one alarm notification will be sent during each silence cycle.
webhook typing.Union[str, ros_cdk_core.IResolvable] Property webhook: When an alarm occurs, the specified URL address will be called back and a POST request will be sent.

group_idRequired

group_id: typing.Union[typing.Union[int, float], IResolvable]
  • Type: typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable]

Property groupId: Apply group ID.

For how to get the application group ID, see DescribeMonitorGroups.


template_idsRequired

template_ids: typing.Union[IResolvable, typing.List[typing.Union[str, IResolvable]]]
  • Type: typing.Union[ros_cdk_core.IResolvable, typing.List[typing.Union[str, ros_cdk_core.IResolvable]]]

Property templateIds: The ID list of the Alarm Template to be applied.

For how to get the alarm template ID, see DescribeMetricRuleTemplateList.


append_modeOptional

append_mode: typing.Union[str, IResolvable]
  • Type: typing.Union[str, ros_cdk_core.IResolvable]

Property appendMode: Template application policy.Value: all: Delete all rules created by the alarm template on the selected group, and then create a new alarm rule by the template (default). append: Delete the rules created by the alarm template on the selected group, and then create a new alarm rule based on the current template.


apply_modeOptional

apply_mode: typing.Union[str, IResolvable]
  • Type: typing.Union[str, ros_cdk_core.IResolvable]

Property applyMode: How to apply templates.Value: GROUP_INSTANCE_FIRST: Application grouping instances are preferred.When applying an alarm template, the application grouping instance is preferred. If the instance does not exist in the application grouping, the rules in the template are ignored. ALARM_TEMPLATE_FIRST: Alarm template instances are preferred.When an alarm template is applied, an alarm rule is created regardless of whether the instance exists in the application group.


enable_end_timeOptional

enable_end_time: typing.Union[typing.Union[int, float], IResolvable]
  • Type: typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable]

Property enableEndTime: The end time when the alarm takes effect.Value range: 0~23, indicating 00:59 to 23:59.


enable_start_timeOptional

enable_start_time: typing.Union[typing.Union[int, float], IResolvable]
  • Type: typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable]

Property enableStartTime: The start time when the alarm takes effect.Value range: 0~23, indicating 00:00 to 23:00.


notify_levelOptional

notify_level: typing.Union[typing.Union[int, float], IResolvable]
  • Type: typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable]

Property notifyLevel: The alert notification method.

Valid values: Set the value to 4. A value of 4 indicates that alert notifications are sent by using TradeManager and DingTalk chatbots.


silence_timeOptional

silence_time: typing.Union[typing.Union[int, float], IResolvable]
  • Type: typing.Union[typing.Union[int, float], ros_cdk_core.IResolvable]

Property silenceTime: Channel silence period.Unit: seconds.Default value: 86400. Note When the monitoring data continues to exceed the alarm rule threshold, only one alarm notification will be sent during each silence cycle.


webhookOptional

webhook: typing.Union[str, IResolvable]
  • Type: typing.Union[str, ros_cdk_core.IResolvable]

Property webhook: When an alarm occurs, the specified URL address will be called back and a POST request will be sent.