Skip to content

RunCommandProps

Properties for defining a RunCommand.

See https://www.alibabacloud.com/help/ros/developer-reference/aliyun-swas-runcommand

Initializer

import "github.com/alibabacloud-go/ros-cdk/alicloudroscdkswas"
&alicloudroscdkswas.RunCommandProps {
    CommandContent: interface{},
    InstanceId: interface{},
    Name: interface{},
    Type: interface{},
    ContentEncoding: interface{},
    EnableParameter: interface{},
    Parameters: interface{},
    Sync: interface{},
    Timeout: interface{},
    WindowsPasswordName: interface{},
    WorkingDir: interface{},
    WorkingUser: interface{},
}

Properties

Name Type Description
CommandContent interface{} Property commandContent: The content of the command.
InstanceId interface{} Property instanceId: The ID of the SWAS instance on which to run the command.
Name interface{} Property name: The name of the command to run.
Type interface{} Property type: The language type of the O&M script.
ContentEncoding interface{} Property contentEncoding: The encoding mode of command content (CommandContent).
EnableParameter interface{} Property enableParameter: Specifies whether the command contains custom parameters.
Parameters interface{} Property parameters: The key-value pairs of custom parameters passed in when the command contains custom parameters.
Sync interface{} Property sync: Whether to run the command synchronously.
Timeout interface{} Property timeout: The timeout period for command execution.
WindowsPasswordName interface{} Property windowsPasswordName: The name of the password to use to run the command on Windows instances.
WorkingDir interface{} Property workingDir: The execution path of the command.
WorkingUser interface{} Property workingUser: The user with which to run the command on the instance.

CommandContentRequired

CommandContent interface{}
  • Type: interface{}

Property commandContent: The content of the command.

Take note of the following items:

  • If you set EnableParameter to true, the custom parameter feature is enabled in the command content and you can configure custom parameters based on the following rules:
  • Define custom parameters in the {{}} format. Within {{}}, the spaces and line feeds before and after the parameter names are ignored.
  • The number of custom parameters cannot be greater than 20.
  • A custom parameter name can contain only letters, digits, underscores (_), and hyphens (-). The name is case-insensitive.
  • Each custom parameter name cannot exceed 64 bytes in length.

InstanceIdRequired

InstanceId interface{}
  • Type: interface{}

Property instanceId: The ID of the SWAS instance on which to run the command.

The instance must be in 'Running' status.


NameRequired

Name interface{}
  • Type: interface{}

Property name: The name of the command to run.


TypeRequired

Type interface{}
  • Type: interface{}

Property type: The language type of the O&M script.

Valid values: RunShellScript: shell scripts for Linux instances RunBatScript: batch scripts for Windows instances RunPowerShellScript: PowerShell scripts for Windows instances


ContentEncodingOptional

ContentEncoding interface{}
  • Type: interface{}

Property contentEncoding: The encoding mode of command content (CommandContent).

Valid values (case insensitive): PlainText: The command content is not encoded, and transmitted in plaintext. Base64: base64-encoded. Default value: PlainText. If the specified value of this parameter is invalid, PlainText is used by default.


EnableParameterOptional

EnableParameter interface{}
  • Type: interface{}

Property enableParameter: Specifies whether the command contains custom parameters.

Default value: false


ParametersOptional

Parameters interface{}
  • Type: interface{}

Property parameters: The key-value pairs of custom parameters passed in when the command contains custom parameters.

Number of custom parameters: 0 to 20. The key cannot be an empty string. It can be up to 64 characters in length. The value can be an empty string. After the custom parameters and the original command content are Base64 encoded, the total size cannot exceed 16 KB. The set of custom parameter names must be a subset of the parameter set that is defined when you created the command. You can use an empty string to represent the parameters that are not passed in. Default value: null, indicating that this parameter is canceled and customer parameters are disabled.


SyncOptional

Sync interface{}
  • Type: interface{}

Property sync: Whether to run the command synchronously.


TimeoutOptional

Timeout interface{}
  • Type: interface{}

Property timeout: The timeout period for command execution.

Unit: seconds. Valid values: 10 to 86400. Default value: 60.


WindowsPasswordNameOptional

WindowsPasswordName interface{}
  • Type: interface{}

Property windowsPasswordName: The name of the password to use to run the command on Windows instances.

The name can be up to 255 characters in length. If you do not want to use the default System user to run the command on Windows instances, specify both WindowsPasswordName and WorkingUser. To mitigate the risk of password leaks, the password is stored in plaintext in Operation Orchestration Service (OOS) Parameter Store, and only the name of the password is passed in by using WindowsPasswordName.


WorkingDirOptional

WorkingDir interface{}
  • Type: interface{}

Property workingDir: The execution path of the command.

Custom paths are supported. Default execution paths vary based on the operating systems of the servers.

  • For Linux servers, the default path is /root of the root user.
  • For Windows servers, the default path is C:\Windows\system32.

WorkingUserOptional

WorkingUser interface{}
  • Type: interface{}

Property workingUser: The user with which to run the command on the instance.

Default value: 'root' for Linux instances, 'system' for Windows instances. You can specify other existing users to run the command to reduce security risks.